Blog · Time windows

Time windows on the data clock

Ask which hour a tendency sits in and the next question is hours on what clock. A StrategyQuant X dataset stores bar times in the zone it was recorded in. If that is not the zone you think it is, every window you find is shifted.

  • Published 2026-11-12

Where the zone comes from

Edge Finder uses the dataset’s declared timezone: an IANA name such as Europe/Berlin, UTC, a fixed offset, or SQX’s own EETUS, the New York close server clock. If the dataset declares none, you type one into the Data clock field. If it still cannot be resolved, windows appear on the data clock only and the session views are off. Nothing is silently assumed to be UTC.

Checking the label

Forex-style markets reopen after the weekend at 17:00 New York. Edge Finder converts each week’s first bar to New York time under the declared zone. A correct label puts every week on the same minute. A feed recorded on a slightly different clock than its label lands an hour early or late in a few weeks only. Those weeks are counted, listed and left out of the scan by default, with a switch to include them. The report also measures the clock from the reopening without using the label, says how many weeks and how good the fit was, and warns if the two disagree. When the history shows only one offset, it says a daylight-saving rule cannot be ruled out.

Indices, stocks and futures have no such anchor. For those the audit says it was skipped, and the label is yours to check.

Why write the window on the data clock

The data clock is also the clock SQX evaluates a Build task’s time range on. A window found on it and written back is self-consistent. It is not the same instant on another feed. A London open is 08:00 London time all year, and it moves against a New York close data clock for about three weeks each spring and autumn. For that reason each window is also shown on UTC, New York and London for a winter and a summer date, and not as one number.

What lands in the task

The Time range row on Deploy writes the Limit time range, switched on, as from and to in seconds after midnight on the data clock. A window across midnight is stored with a From later than the To, which is how SQX reads an overnight range. A window ending at 24:00 is stored with a To of 00:00. The weekday set is not written. If your trading broker’s clock differs from the data clock, check the converted times under the window before you trade it.

Related

The full description is on the Time Windows page. See also Session filter in StrategyQuant X.

Risk

Trading leveraged instruments carries a high risk of loss. Software output is not investment advice and says nothing about future results. Validate every strategy yourself before risking capital.